TEMPERATURE · FROZEN DISCOVERY CAMPAIGN
Temperature validation
Comparison of the residual model, GLORYS and baselines against held-out temperature profiles.
Conditioning and evaluation protocol
01 / ConditioningAll QC-valid EN4 context in each matched patch and time window, including profiles potentially assimilated into GLORYS. Evaluation target cells are withheld; Italian XBT targets also have a one-cell buffer.
02 / EvaluationAll 102 Italian XBT casts from both missions are evaluated. The separate preliminary EN4 evaluation uses 64 patches spanning all 12 months.
03 / InterpretationThe profiles belong to the documented screened set. This does not prove that GLORYS never used them. Original tables use one field per case; the separate Italian ensemble analysis uses 20 samples.
EN4 results pending
The preliminary run uses 64 patches from the frozen 256-patch sample, split across two GPUs. Tables, depth curves and individual profiles will appear here after the saved results have passed evaluation and the site snapshot is refreshed.
Download tables and figures (ZIP) · Depth table (CSV) · Methods and provenance (JSON)
Original single-generation temperature errors
Equal weight per profile. Each cast counts equally. Lower errors are better. All values are in °C; use the information buttons for definitions.
| Method | MAE | RMSE | CRPS | Δ MAE vs GLORYS |
|---|
Errors by depth
Show the depth table
| Method | Depth (m) | Profiles | Points | MAE | RMSE | Bias | CRPS |
|---|
Observed and predicted profiles
All 102 Italian casts from both missions are available. Mission colours and map layers show where they were collected. Curves retain all saved observation depths. Click a location to select its cast; use the legend to compare additional methods.
Probabilistic and spatial metrics
CRPS against withheld XBT observations
Lower CRPS is better. Fair CRPS adjusts for finite ensemble size. Coverage shows how often the central 90% interval contains the observation; width is in °C. Deterministic baselines have no interval diagnostics.
| Method | Samples | CRPS · °C | Fair CRPS · °C | 90% coverage | 90% width · °C |
|---|
LPIPS and spectral error against packaged GLORYS
LPIPS uses each temperature depth layer repeated across RGB and one fixed temperature scale. It is an exploratory natural-image metric. Spectral error compares log power across wavelengths from 30 to 1,000 km. Lower is better for both; matching spectra does not establish correct feature locations. Individual sample scores and the ensemble mean are reported separately.
| Method | Shared patches | LPIPS · VGG | Spectral log₁₀ RMSE |
|---|
Wavenumber spectra
Ensemble and spatial scoring methods
Errors by mission
Download CSV ↓Each mission is scored separately as well as in the combined table. Every cast counts equally within its mission.
| Mission | Method | MAE | RMSE |
|---|
Conditioning sensitivity
These experiments use 0, 1, 2, 4, 8, or all available EN4 input locations per patch. The main comparison uses all available inputs after target masking. Each cast counts equally.
Spatial predictions by depth
Full-context predictions and reference fields on the original model grid. All panels use the same depth and colour scale. Images are reconstructed using the recorded inputs and seeds. Pointwise agreement is verified for scored methods; IDW is descriptive because complete point support is unavailable. The default patch is selected for having more than five XBT casts and more than five EN4 input cells, not for prediction accuracy. Spatial images cover all 14 saved Italian patches from both missions.
Loading spatial image availability…
Playback advances every 0.5 seconds and loops through the depth levels. The slider, arrow buttons and scrolling also change depth and pause playback. Cyan circles: EN4 supports (filled at valid depths). White crosses: XBT casts; red: selected cast. Transparent pixels denote missing reference or model support.
Analysis status
Limitations and provenance
- The 2016 discovery year informed checkpoint selection. These results do not establish independent confirmation.
- Italian XBT QF=1 corrected temperatures are converted to potential temperature with TEOS-10 using GLORYS salinity. Predictions are interpolated to native observation depths.
- Italian evaluation uses 102 casts from two missions. Two missions are too few for reliable uncertainty ranges or broad significance claims.
- GLORYS here is the packaged reference, with approximately 0.15 °C quantization. Native floating-point GLORYS is required before a delivered-product superiority claim.
- Single-generation CRPS equals absolute error. The Italian ensemble section evaluates sampled uncertainty separately; LPIPS and spectra compare dense fields with GLORYS, not with XBT observations.
- Target cells are masked across overlapping patches; Italian XBT targets also have a one-cell buffer. Complete cruise-level conditioning exclusion cannot be verified without cluster identities in the compact context store.